MeterLogix POU System Technical Specifications

i-metertm Characteristics
Maximum flow rate for continuous duty 8.0 gpm
Nominal flow range .25 to 8 gpm
Minimum flow .10 gpm
Maximum working pressure 150 psi
Maximum working temperature 180o F
Pressure drop .75 psi @ 2gpm
Meets AWWA Accuracy Requirements +/- 1.5% at nominal flow
Typical pipe size 1/2"
Weight 2 oz.
i-metertm life 20+ years
spacer
i-metertm Materials
Engineered Plastic (Noryl®)
Meter body and components Stainless Steel Shaft
FDA Approved Silicone Washer
Spacer
Meter Interface Card (4 or 8 ports)
i-metertm connections Up to 4 or 8 i-metertms
Battery type CR123A (Replaceable)
Battery life 8 year life
Operating temperature -10o F to + 135o F
Storage temperature -40o F to +160o F
Meter Output Industry Standard Pulse output:
10ms @ 3VDC (1 pulse per gallon)